Honeywell Searchpoint Optima Plus OPTIMACALKIT-HC – Calibration: Optima Plus Calibration Gas Cylinder - Hydrocarbon mix (CH4 in air)

OPTIMACALKIT-HC is a Searchpoint Optima Plus Calibration: Optima Plus Calibration Gas Cylinder - Hydrocarbon mix (CH4 in air). It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

OPTIMACALKIT-HC is a Calibration; see same-class SKUs in the matrix.

OPTIMACALKIT-HC Honeywell Searchpoint Optima Plus Hydrocarbon Calibration

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Calibration Gas Cylinder - Hydrocarbon mix (CH4 in air)OPTIMACALKIT-HC
ClassAccessoryCalibration

Technical specifications

CategoryAccessory / Calibration
DescriptionOptima Plus Calibration Gas Cylinder - Hydrocarbon mix (CH4 in air)
GasHydrocarbon
Output
Approvalssee description
Entries
Enclosure
RGCno
PrinciplePoint IR (dual source, dual beam)
Range
Ingress随本体

Why this part number

Keep OPTIMACALKIT-HC on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

OPTIMACALKIT-HC is Searchpoint Optima Plus Calibration. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use OPTIMACALKIT-HC against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0280Calibration
2108B0283Calibration
2108B0284Calibration
2108B0285Calibration
OPTIMACALKITCalibration
OPTIMACALKIT-ETCalibrationEthylene
OPTIMACALKIT-ZEROCalibration

Optima Plus family matrix

Installation and service

Isolate power before swapping OPTIMACALKIT-HC. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Will OPTIMACALKIT-HC detect gas by itself?
No. OPTIMACALKIT-HC is a Calibration (Optima Plus Calibration Gas Cylinder - Hydrocarbon mix (CH4 in air)) and needs an Optima Plus detector body.
Can I fit an XCD/XNX spare instead of OPTIMACALKIT-HC?
No. Optima optics, seals and connectors are unique.
Which detector does OPTIMACALKIT-HC mate with?
New builds: current 2108N SKUs such as 2108N4000N. Installed base: read the 2108B/2108N nameplate first.
Thread mix-ups?
Yes. Glands, plugs and adaptors split M20 / M25 / 3/4" NPT. Copy the detector nameplate.
Calibrate after fitting?
Zero and span after window, lamp or detector swaps. Brackets and tags do not need gas.
Lead time?
Lot-based. Do not substitute a look-alike OPTIMA* SKU without matching the part number.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Stock is lot-based. If OPTIMACALKIT-HC is out, jump to — / —.

WhatsAppTop