Honeywell Searchpoint Optima Plus OPTIMACALKIT – Calibration: Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case)
OPTIMACALKIT is a Searchpoint Optima Plus Calibration: Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case). It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.
OPTIMACALKIT is a Calibration; see same-class SKUs in the matrix.

Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| Family | Honeywell Searchpoint Optima Plus point IR | Optima Plus |
| P/N | Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case) | OPTIMACALKIT |
| Class | Accessory | Calibration |
Technical specifications
| Category | Accessory / Calibration |
|---|---|
| Description | Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case) |
| Gas | — |
| Output | — |
| Approvals | see description |
| Entries | — |
| Enclosure | — |
| RGC | — |
| Principle | Point IR (dual source, dual beam) |
| Range | — |
| Ingress | 随本体 |
Why this part number
Keep OPTIMACALKIT on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.
Spares and mates
OPTIMACALKIT is Searchpoint Optima Plus Calibration. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.
Typical applications
Use OPTIMACALKIT against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.
Selection contrast
| P/N | Type | Gas | Cert | Output |
|---|---|---|---|---|
| 2108B0280 | Calibration | — | — | — |
| 2108B0283 | Calibration | — | — | — |
| 2108B0284 | Calibration | — | — | — |
| 2108B0285 | Calibration | — | — | — |
| OPTIMACALKIT-HC | Calibration | Hydrocarbon | — | — |
| OPTIMACALKIT-ET | Calibration | Ethylene | — | — |
| OPTIMACALKIT-ZERO | Calibration | — | — | — |
Installation and service
Isolate power before swapping OPTIMACALKIT. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.
FAQ
- Will OPTIMACALKIT detect gas by itself?
- No. OPTIMACALKIT is a Calibration (Optima Plus Calibration Kit (includes calibration cup,hose,regulator,carrying case)) and needs an Optima Plus detector body.
- Can I fit an XCD/XNX spare instead of OPTIMACALKIT?
- No. Optima optics, seals and connectors are unique.
- Which detector does OPTIMACALKIT mate with?
- New builds: current 2108N SKUs such as 2108N4000N. Installed base: read the 2108B/2108N nameplate first.
- Thread mix-ups?
- Yes. Glands, plugs and adaptors split M20 / M25 / 3/4" NPT. Copy the detector nameplate.
- Calibrate after fitting?
- Zero and span after window, lamp or detector swaps. Brackets and tags do not need gas.
- Lead time?
- Lot-based. Do not substitute a look-alike OPTIMA* SKU without matching the part number.
Documents
Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix
Availability and enquiry
Stock is lot-based. If OPTIMACALKIT is out, jump to — / —.