Honeywell Searchpoint Optima Plus OPTIMADESICCANT – Consumable: Optima Plus Desiccant Cartridge Replacement Kit

OPTIMADESICCANT is a Searchpoint Optima Plus Consumable: Optima Plus Desiccant Cartridge Replacement Kit. It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

OPTIMADESICCANT is a Consumable; see same-class SKUs in the matrix.

OPTIMADESICCANT Honeywell Searchpoint Optima Plus — Consumable

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Desiccant Cartridge Replacement KitOPTIMADESICCANT
ClassSpareConsumable

Technical specifications

CategorySpare / Consumable
DescriptionOptima Plus Desiccant Cartridge Replacement Kit
Gas
Output
Approvalssee description
Entries
Enclosure
RGC
PrinciplePoint IR (dual source, dual beam)
Range
Ingress随本体

Why this part number

Keep OPTIMADESICCANT on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

OPTIMADESICCANT is Searchpoint Optima Plus Consumable. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use OPTIMADESICCANT against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108B0259Consumable
2108B0260Consumable
2108B0299Consumable
2108B0300Consumable
OPTIMADUSTBARRIERConsumable

Optima Plus family matrix

Installation and service

Isolate power before swapping OPTIMADESICCANT. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Will OPTIMADESICCANT detect gas by itself?
No. OPTIMADESICCANT is a Consumable (Optima Plus Desiccant Cartridge Replacement Kit) and needs an Optima Plus detector body.
Can I fit an XCD/XNX spare instead of OPTIMADESICCANT?
No. Optima optics, seals and connectors are unique.
Which detector does OPTIMADESICCANT mate with?
New builds: current 2108N SKUs such as 2108N4000N. Installed base: read the 2108B/2108N nameplate first.
Thread mix-ups?
Yes. Glands, plugs and adaptors split M20 / M25 / 3/4" NPT. Copy the detector nameplate.
Calibrate after fitting?
Zero and span after window, lamp or detector swaps. Brackets and tags do not need gas.
Lead time?
Lot-based. Do not substitute a look-alike OPTIMA* SKU without matching the part number.