Honeywell Sensepoint XCD SPXCDASMPX – Fixed C₃H₈ Detector (0-100%LEL, Infrared (dual-beam), ATEX, 316SS, M20)

SPXCDASMPX is the Sensepoint XCD infrared propane LEL transmitter, 0–100 %LEL, 316 stainless steel, 2 × M20, ATEX / IECEx / GB. Order it for LPG bullet farms and cylinder filling halls where methane IR would under-read.

Same gas, swap enclosure/approval: aluminium SPXCDALMPX, 316SS SPXCDASMPX, UL SPXCDULNPX. SPXCDALMPX · SPXCDASMPX · SPXCDULNPX

SPXCDASMPX Honeywell Sensepoint XCD C3H8 detector 316SS M20

Part-number decode

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSS
M / NEntry M=M20; N=3/4" NPTM
PXGas propane, Infrared (dual-beam)PX

Same gas, swap enclosure/approval: aluminium SPXCDALMPX, 316SS SPXCDASMPX, UL SPXCDULNPX.

Technical specifications

Target gasC₃H₈ / propane
PrincipleInfrared (dual-beam)
Default range0-100%LEL
User FSD window20-100%LEL
Resolution10%LEL
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
Enclosure316 stainless steel
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 3.1 kg (6.8 lb)

Why this principle for this gas

Propane is heavier than air and slides along floors toward pits. Dual-beam IR tuned for C₃ is used so a methane-calibrated pellistor or RX cell cannot hide a rich LPG layer. Mount 200–400 mm above grade, at the pit lip, not on the roof.

Sensor and replaceable parts

OEM cartridge SPXCDXSPXSS. Calibration cap S3KCAL. Collecting cone follows buoyancy—see installation. Pipe/duct kits: SPXCDMTBR / SPXCDDMK.

Typical applications

LPG tank farms, bottle-filling halls and kitchen-gas manifolds need a propane-specific IR trip. XCD gives a hard-wired 4–20 mA to the tank ESD; a handheld only proves the aisle you walked.

Selection contrast

P/NGasRangePrinciple
SPXCDASMPXC₃H₈0-100%LELIR
SPXCDASMRXCH₄0-100%LELIR
SPXCDASMFXLEL0-100%LELCatalytic bead
SPXCDASMB1CO₂0-2.00%VolIR
SPXCDALMPXC₃H₈0-100%LELIR
SPXCDULNPXC₃H₈0-100%LELIR

XCD family matrix

Installation and wiring

Wall-mount SPXCDASMPX (propane, 316 stainless steel) through the one-piece plate with M8 bolts sized for that mass. This SKU uses 2 × M20 entries: pipe kit SPXCDMTBR covers Ø1.5–3″, duct kit is SPXCDDMK, and glands must match—do not retap SPXCDASMPX. Land SPXCDASMPX 4–20 mA as three-wire and set Modbus address from the menu only. Magnetic wand calibration on the SPXCDASMPX lid stays non-intrusive. SPXCDASMPX propane belongs at the pit lip, not the roof.

FAQ

SPXCDASMPX: Can I use methane IR (RX) on an LPG skid?
SPXCDASMPX — No. Response curves differ. Specify PX or you will under-alarm a propane release.
SPXCDASMPX: Does PX work in oxygen-free vapour spaces?
SPXCDASMPX — Yes. IR does not combust the sample, so inerted LPG vapour spaces remain measurable.
What weight penalty does 316SS add on SPXCDASMPX?
SPXCDASMPX is ~6.8 lb versus ~4.4 lb for aluminium sibling SPXCDALMPX. The extra mass buys chloride resistance for this propane point; keep M8 wall bolts at the stamped size.
Can I convert SPXCDASMPX from ATEX M20 to NPT in the field?
No. SPXCDASMPX flameproof entries are machined M20. North-American NPT is UL sibling SPXCDULNPX, not an adaptor on this ATEX propane body.
Can I retrofit Modbus on SPXCDASMPX after it ships?
Modbus RTU on SPXCDASMPX is a transmitter sales option, not a jumper on the propane lid. Confirm the option before the box leaves; 4–20 mA sink/source is already on this SKU.

Documents

Honeywell Sensepoint XCD datasheet / manual · On-site XCD selection matrix

Availability and enquiry

Stock is lot-based. If this aluminium ATEX box is out, jump to 316SS SPXCDASMPX or UL SPXCDULNPX rather than a dead SKU.