Honeywell Sensepoint XCD SPXCDASNNX – Fixed NO₂ Detector (0-50ppm, Electrochemical (Surecell™), ATEX, 316SS, M20)

SPXCDASNNX is the Sensepoint XCD nitrogen dioxide electrochemical transmitter, 0–50 ppm default, 316 stainless steel, 2 × M20, ATEX / IECEx / GB. It is aimed at diesel halls, tunnel plant rooms and nitric-acid fill points.

Same gas, swap enclosure/approval: aluminium SPXCDALMNX, 316SS SPXCDASNNX, UL SPXCDULNNX. SPXCDALMNX · SPXCDASNNX · SPXCDULNNX

SPXCDASNNX Honeywell Sensepoint XCD NO2 detector 316SS M20

Part-number decode

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSS
M / NEntry M=M20; N=3/4" NPTM
NXGas nitrogen dioxide, Electrochemical (Surecell™)NX

Same gas, swap enclosure/approval: aluminium SPXCDALMNX, 316SS SPXCDASNNX, UL SPXCDULNNX.

Technical specifications

Target gasNO₂ / nitrogen dioxide
PrincipleElectrochemical (Surecell™)
Default range0-50ppm
User FSD window10-50ppm
Resolution5ppm
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
Enclosure316 stainless steel
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 3.1 kg (6.8 lb)

Why this principle for this gas

NO₂ is heavier than air and rides exhaust plumes toward floor trenches. Surecell™ electrochemistry is required; IR and catalytic channels do not quantify NO₂. Mount low on the exhaust side of the engine hall, not on the fresh-air intake.

Sensor and replaceable parts

OEM cartridge SPXCDXSN1SS. Calibration cap S3KCAL. Collecting cone follows buoyancy—see installation. Pipe/duct kits: SPXCDMTBR / SPXCDDMK.

Typical applications

Standby-generator rooms, road-tunnel niches and fertiliser fill bays need a dedicated NO₂ point tied to extract fans. XCD holds that interlock; a badge dosimeter only explains the exposure after the fact.

Selection contrast

P/NGasRangePrinciple
SPXCDASNNXNO₂0-50ppmEChem
SPXCDASMCXCO0-300ppmEChem
SPXCDASMHXH₂S0-50ppmEChem
SPXCDASMO1O₂0-25.0%VolEChem
SPXCDALMNXNO₂0-50ppmEChem
SPXCDULNNXNO₂0-50ppmEChem

XCD family matrix

Installation and wiring

Wall-mount SPXCDASNNX (nitrogen dioxide, 316 stainless steel) through the one-piece plate with M8 bolts sized for that mass. This SKU uses 2 × M20 entries: pipe kit SPXCDMTBR covers Ø1.5–3″, duct kit is SPXCDDMK, and glands must match—do not retap SPXCDASNNX. Land SPXCDASNNX 4–20 mA as three-wire and set Modbus address from the menu only. Magnetic wand calibration on the SPXCDASNNX lid stays non-intrusive. SPXCDASNNX NO₂ sits low on the exhaust wall.

FAQ

SPXCDASNNX: Does the NX cell also read NO?
SPXCDASNNX — It is specified for NO₂. If you have nitric oxide you need a different cartridge family—do not assume NX covers both.
SPXCDASNNX: What FSD options exist?
SPXCDASNNX — Default 0–50 ppm, user window 10–50 ppm in 5 ppm steps. Tunnel niches usually stay at 20 ppm FSD.
What weight penalty does 316SS add on SPXCDASNNX?
SPXCDASNNX is ~6.8 lb versus ~4.4 lb for aluminium sibling SPXCDALMNX. The extra mass buys chloride resistance for this nitrogen dioxide point; keep M8 wall bolts at the stamped size.
Can I convert SPXCDASNNX from ATEX M20 to NPT in the field?
No. SPXCDASNNX flameproof entries are machined M20. North-American NPT is UL sibling SPXCDULNNX, not an adaptor on this ATEX nitrogen dioxide body.
Can I retrofit Modbus on SPXCDASNNX after it ships?
Modbus RTU on SPXCDASNNX is a transmitter sales option, not a jumper on the nitrogen dioxide lid. Confirm the option before the box leaves; 4–20 mA sink/source is already on this SKU.

Documents

Honeywell Sensepoint XCD datasheet / manual · On-site XCD selection matrix

Availability and enquiry

Stock is lot-based. If this aluminium ATEX box is out, jump to 316SS SPXCDASNNX or UL SPXCDULNNX rather than a dead SKU.