Honeywell Sensepoint XCD SPXCDULNHX – Fixed H₂S Detector (0-50ppm, Electrochemical (Surecell™), UL, LM25, 3/4" NPT)

SPXCDULNHX is the Honeywell Sensepoint XCD transmitter factory-fitted for hydrogen sulfide, default 0–50 ppm electrochemical range, LM25 epoxy-coated aluminium and 2 × 3/4" NPT cable entries, UL / CSA certified. Specify it when a fixed H2S point must stay online at a wastewater headworks, sour-water pit or offshore well bay instead of sending a portable every shift.

Same gas, swap enclosure/approval: aluminium SPXCDALMHX, 316SS SPXCDASMHX, UL SPXCDULNHX. SPXCDALMHX · SPXCDASMHX · SPXCDULNHX

SPXCDULNHX Honeywell Sensepoint XCD H2S detector LM25 3/4" NPT

Part-number decode

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULU
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4" NPTN
HXGas hydrogen sulfide, Electrochemical (Surecell™)HX

Same gas, swap enclosure/approval: aluminium SPXCDALMHX, 316SS SPXCDASMHX, UL SPXCDULNHX.

Technical specifications

Target gasH₂S / hydrogen sulfide
PrincipleElectrochemical (Surecell™)
Default range0-50ppm
User FSD window10-100ppm
Resolution1ppm
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium
Entries2 × 3/4" NPT
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsUL / CSA
Temperature−40~+65 ℃
Massapprox. 2.0 kg (4.4 lb)

Why this principle for this gas

H₂S is denser than air and collects in sumps, wet wells and trench bottoms. An electrochemical Surecell™ cartridge is used because it is selective at tens of ppm and supports Reflex™ electrode check; a pellistor would ignore the toxic risk and a semiconductor cell would drift in wet H₂S. Mount the sensor 300–500 mm above the lowest floor, never in the splash zone, and do not fit a weather cone that traps heavier-than-air gas against the sinter.

Sensor and replaceable parts

OEM cartridge SPXCDXSHXSS. Calibration cap S3KCAL. Fit a collecting cone on hydrogen; do not cone a heavier-than-air H₂S head. Pipe/duct kits: SPXCDMTBR / SPXCDDMK.

Typical applications

Typical fixed H₂S points are wastewater wet wells, refinery sulphur pits, landfill biogas headers and battery rooms with sulphide off-gassing. XCD stays on the wall, accepts a remote sensor up to 30 m if the transmitter must sit outside the splash zone, and is magnet-calibrated without opening the flameproof lid—none of which a portable can do on a 15-minute tour.

Selection contrast

P/NGasRangePrinciple
SPXCDULNHXH₂S0-50ppmEChem
SPXCDULNCXCO0-300ppmEChem
SPXCDULNO1O₂0-25.0%VolEChem
SPXCDULNRXCH₄0-100%LELIR
SPXCDALMHXH₂S0-50ppmEChem
SPXCDASMHXH₂S0-50ppmEChem

XCD family matrix

Installation and wiring

Wall-mount SPXCDULNHX (hydrogen sulfide, LM25 epoxy-coated aluminium) through the one-piece plate with M8 bolts sized for that mass. This SKU uses 2 × 3/4" NPT entries: pipe kit SPXCDMTBR covers Ø1.5–3″, duct kit is SPXCDDMK, and glands must match—do not retap SPXCDULNHX. Land SPXCDULNHX 4–20 mA as three-wire and set Modbus address from the menu only. Magnetic wand calibration on the SPXCDULNHX lid stays non-intrusive. On SPXCDULNHX keep the H₂S head low and skip the weather cone.

FAQ

Does SPXCDULNHX measure anything other than H₂S?
SPXCDULNHX — No. The HX cartridge is H₂S-only. To change gas you replace the sensor housing SPXCDXSHXSS or order a different transmitter SKU.
SPXCDULNHX: How does Reflex™ affect H₂S cell life?
SPXCDULNHX — Reflex™ pulses the electrode and flags decline before the 2–3 year electrochemical life is exhausted. Budget a spare SPXCDXSHXSS at the 24-month mark for continuous H₂S service.
LM25 or 316SS for SPXCDULNHX (hydrogen sulfide)?
SPXCDULNHX ships in LM25 epoxy aluminium (~4.4 lb). For hydrogen sulfide in salt spray, caustic CIP or sour-water splash, switch to 316SS sibling SPXCDASMHX instead of painting this lid.
Why is SPXCDULNHX NPT instead of M20?
SPXCDULNHX is the UL/CSA hydrogen sulfide body and ships 3/4" NPT. Do not tap M20 on this lid—order ATEX sibling SPXCDALMHX if metric glands are mandatory.
Can I retrofit Modbus on SPXCDULNHX after it ships?
Modbus RTU on SPXCDULNHX is a transmitter sales option, not a jumper on the hydrogen sulfide lid. Confirm the option before the box leaves; 4–20 mA sink/source is already on this SKU.

Documents

Honeywell Sensepoint XCD datasheet / manual · On-site XCD selection matrix

Availability and enquiry

Stock is lot-based. If this aluminium ATEX box is out, jump to 316SS SPXCDASMHX or UL SPXCDULNHX rather than a dead SKU.