Honeywell Sensepoint XCD SPXCDULNO1 – Fixed O₂ Detector (0-25.0%Vol, Electrochemical (Surecell™), UL, LM25, 3/4" NPT)

SPXCDULNO1 is the Sensepoint XCD oxygen deficiency / enrichment transmitter, fixed 0–25.0 %vol electrochemical cell, LM25 epoxy-coated aluminium, 2 × 3/4" NPT, UL / CSA. It is the dedicated O₂ SKU for nitrogen-purged vessels, confined plant rooms and inerting skids.

Same gas, swap enclosure/approval: aluminium SPXCDALMO1, 316SS SPXCDASMO1, UL SPXCDULNO1. SPXCDALMO1 · SPXCDASMO1 · SPXCDULNO1

SPXCDULNO1 Honeywell Sensepoint XCD O2 detector LM25 3/4" NPT

Part-number decode

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULU
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4" NPTN
O1Gas oxygen, Electrochemical (Surecell™)O1

Same gas, swap enclosure/approval: aluminium SPXCDALMO1, 316SS SPXCDASMO1, UL SPXCDULNO1.

Technical specifications

Target gasO₂ / oxygen
PrincipleElectrochemical (Surecell™)
Default range0-25.0%Vol
User FSD windowFixed 25.0%Vol
Resolutionn/a
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium
Entries2 × 3/4" NPT
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsUL / CSA
Temperature−40~+65 ℃
Massapprox. 2.0 kg (4.4 lb)

Why this principle for this gas

Oxygen is neither heavier nor lighter in a meaningful way for siting—the risk is displacement by N₂ or enrichment from leaks. A Surecell™ O₂ cell is used because catalytic and IR channels cannot report %vol oxygen. Mount at the height where personnel breathe or where the purge first enters; do not hide it behind a vessel skirt.

Sensor and replaceable parts

OEM cartridge SPXCDXSO1SS. Calibration cap S3KCAL. Collecting cone follows buoyancy—see installation. Pipe/duct kits: SPXCDMTBR / SPXCDDMK.

Typical applications

Nitrogen-inerted tanks, analyser houses and bottle stores need a latched O₂ trip, not a walk-around reading. XCD gives 4–20 mA plus relays so the purge skid can hard-interlock; a portable cannot hold that permit.

Selection contrast

P/NGasRangePrinciple
SPXCDULNO1O₂0-25.0%VolEChem
SPXCDULNHXH₂S0-50ppmEChem
SPXCDULNCXCO0-300ppmEChem
SPXCDULNFXLEL0-100%LELCatalytic bead
SPXCDALMO1O₂0-25.0%VolEChem
SPXCDASMO1O₂0-25.0%VolEChem

XCD family matrix

Installation and wiring

Wall-mount SPXCDULNO1 (oxygen, LM25 epoxy-coated aluminium) through the one-piece plate with M8 bolts sized for that mass. This SKU uses 2 × 3/4" NPT entries: pipe kit SPXCDMTBR covers Ø1.5–3″, duct kit is SPXCDDMK, and glands must match—do not retap SPXCDULNO1. Land SPXCDULNO1 4–20 mA as three-wire and set Modbus address from the menu only. Magnetic wand calibration on the SPXCDULNO1 lid stays non-intrusive. Aim the SPXCDULNO1 O₂ head at the purge inlet or the breathing line.

FAQ

SPXCDULNO1: Can I change the 25 %vol O₂ FSD?
SPXCDULNO1 — No. The O1 cell is fixed at 25.0 %vol. If you need a different span you are specifying the wrong platform.
SPXCDULNO1: How often is an oxygen cell replaced?
SPXCDULNO1 — Plan 12–18 months in continuously powered service. Keep SPXCDXSO1SS on the shelf; oxygen cells age even in the box once the foil is broken.
LM25 or 316SS for SPXCDULNO1 (oxygen)?
SPXCDULNO1 ships in LM25 epoxy aluminium (~4.4 lb). For oxygen in salt spray, caustic CIP or sour-water splash, switch to 316SS sibling SPXCDASMO1 instead of painting this lid.
Why is SPXCDULNO1 NPT instead of M20?
SPXCDULNO1 is the UL/CSA oxygen body and ships 3/4" NPT. Do not tap M20 on this lid—order ATEX sibling SPXCDALMO1 if metric glands are mandatory.
Can I retrofit Modbus on SPXCDULNO1 after it ships?
Modbus RTU on SPXCDULNO1 is a transmitter sales option, not a jumper on the oxygen lid. Confirm the option before the box leaves; 4–20 mA sink/source is already on this SKU.

Documents

Honeywell Sensepoint XCD datasheet / manual · On-site XCD selection matrix

Availability and enquiry

Stock is lot-based. If this aluminium ATEX box is out, jump to 316SS SPXCDASMO1 or UL SPXCDULNO1 rather than a dead SKU.