Honeywell Sensepoint XCD SPXCDASMB2 – Fixed CO₂ Detector (0-5.00%Vol, Infrared (dual-beam), ATEX, 316SS, M20)

SPXCDASMB2 is the Sensepoint XCD infrared carbon dioxide transmitter at 0–5.00 %vol, 316 stainless steel, 2 × M20, ATEX / IECEx / GB. It is the process-range SKU for fermentation heads and bulk CO₂ vaporisers, not the 2 %vol occupied-room B1.

Same gas, swap enclosure/approval: aluminium SPXCDALMB2, 316SS SPXCDASMB2, UL —. SPXCDALMB2 · SPXCDASMB2 · —

SPXCDASMB2 Honeywell Sensepoint XCD CO2 detector 316SS M20

Part-number decode

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULA
L / SEnclosure L=LM25 aluminium; S=316SSS
M / NEntry M=M20; N=3/4" NPTM
B2Gas carbon dioxide 5 %vol, Infrared (dual-beam)B2

Same gas, swap enclosure/approval: aluminium SPXCDALMB2, 316SS SPXCDASMB2, UL —.

Technical specifications

Target gasCO₂ / carbon dioxide 5 %vol
PrincipleInfrared (dual-beam)
Default range0-5.00%Vol
User FSD windowFixed 5.00%Vol
Resolutionn/a
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
Enclosure316 stainless steel
Entries2 × M20
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsATEX / IECEx / GB
Temperature−40~+65 ℃
Massapprox. 3.1 kg (6.8 lb)

Why this principle for this gas

At 5 %vol the atmosphere is already an asphyxiation process stream. Dual-beam IR is mandatory; a 2 %vol B1 cell would peg. Mount at the fermentation headspace or vaporiser pit lip, low because CO₂ slumps, and specify 316SS if caustic CIP mist is present.

Sensor and replaceable parts

OEM cartridge —. Calibration cap S3KCAL. Collecting cone follows buoyancy—see installation. Pipe/duct kits: SPXCDMTBR / SPXCDDMK.

Typical applications

Brewhouse fermenters, dry-ice rooms and bulk CO₂ vaporizers need a 5 %vol hard trip. XCD keeps the interlock on the wall; a portable cannot sit in that atmosphere.

Selection contrast

P/NGasRangePrinciple
SPXCDASMB2CO₂0-5.00%VolIR
SPXCDASMB1CO₂0-2.00%VolIR
SPXCDASMRXCH₄0-100%LELIR
SPXCDASMO1O₂0-25.0%VolEChem
SPXCDALMB2CO₂0-5.00%VolIR

XCD family matrix

Installation and wiring

Wall-mount SPXCDASMB2 (carbon dioxide 5 %vol, 316 stainless steel) through the one-piece plate with M8 bolts sized for that mass. This SKU uses 2 × M20 entries: pipe kit SPXCDMTBR covers Ø1.5–3″, duct kit is SPXCDDMK, and glands must match—do not retap SPXCDASMB2. Land SPXCDASMB2 4–20 mA as three-wire and set Modbus address from the menu only. Magnetic wand calibration on the SPXCDASMB2 lid stays non-intrusive. SPXCDASMB2 5 %vol CO₂ belongs at the fermenter head or vaporiser pit.

FAQ

SPXCDASMB2: Can B2 replace B1 in a control room?
SPXCDASMB2 — No. 5 %vol FSD is too coarse for occupied rooms. Use B1 at 2 %vol.
SPXCDASMB2: Is there a UL version of B2 in this matrix?
SPXCDASMB2 — Not in the current published XCD STD list. If UL is mandatory, discuss a different enclosure/entry combination with applications.
What weight penalty does 316SS add on SPXCDASMB2?
SPXCDASMB2 is ~6.8 lb versus ~4.4 lb for aluminium sibling SPXCDALMB2. The extra mass buys chloride resistance for this carbon dioxide 5 %vol point; keep M8 wall bolts at the stamped size.
Can I convert SPXCDASMB2 from ATEX M20 to NPT in the field?
No. SPXCDASMB2 flameproof entries are machined M20. North-American NPT is UL sibling —, not an adaptor on this ATEX carbon dioxide 5 %vol body.
Can I retrofit Modbus on SPXCDASMB2 after it ships?
Modbus RTU on SPXCDASMB2 is a transmitter sales option, not a jumper on the carbon dioxide 5 %vol lid. Confirm the option before the box leaves; 4–20 mA sink/source is already on this SKU.

Documents

Honeywell Sensepoint XCD datasheet / manual · On-site XCD selection matrix

Availability and enquiry

Stock is lot-based. If this aluminium ATEX box is out, jump to 316SS SPXCDASMB2 or UL — rather than a dead SKU.