Honeywell Sensepoint XCD SPXCDULNNX – Fixed NO₂ Detector (0-50ppm, Electrochemical (Surecell™), UL, LM25, 3/4" NPT)

SPXCDULNNX is the Sensepoint XCD nitrogen dioxide electrochemical transmitter, 0–50 ppm default, LM25 epoxy-coated aluminium, 2 × 3/4" NPT, UL / CSA. It is aimed at diesel halls, tunnel plant rooms and nitric-acid fill points.

Same gas, swap enclosure/approval: aluminium SPXCDALMNX, 316SS SPXCDASNNX, UL SPXCDULNNX. SPXCDALMNX · SPXCDASNNX · SPXCDULNNX

SPXCDULNNX Honeywell Sensepoint XCD NO2 detector LM25 3/4" NPT

Part-number decode

SegmentMeaningThis SKU
SPXCDSensepoint XCD seriesSPXCD
A / UApproval A=ATEX/IECEx/GB; U=ULU
L / SEnclosure L=LM25 aluminium; S=316SSL
M / NEntry M=M20; N=3/4" NPTN
NXGas nitrogen dioxide, Electrochemical (Surecell™)NX

Same gas, swap enclosure/approval: aluminium SPXCDALMNX, 316SS SPXCDASNNX, UL SPXCDULNNX.

Technical specifications

Target gasNO₂ / nitrogen dioxide
PrincipleElectrochemical (Surecell™)
Default range0-50ppm
User FSD window10-50ppm
Resolution5ppm
Output4–20 mA sink/source + optional Modbus RTU
Supply16–32 VDC (24 VDC nominal)
Power3.7 W
EnclosureLM25 epoxy-coated aluminium
Entries2 × 3/4" NPT
DisplayTri-colour backlight LCD
Relays3×5A@250VAC
IngressIP66
ApprovalsUL / CSA
Temperature−40~+65 ℃
Massapprox. 2.0 kg (4.4 lb)

Why this principle for this gas

NO₂ is heavier than air and rides exhaust plumes toward floor trenches. Surecell™ electrochemistry is required; IR and catalytic channels do not quantify NO₂. Mount low on the exhaust side of the engine hall, not on the fresh-air intake.

Sensor and replaceable parts

OEM cartridge SPXCDXSN1SS. Calibration cap S3KCAL. Collecting cone follows buoyancy—see installation. Pipe/duct kits: SPXCDMTBR / SPXCDDMK.

Typical applications

Standby-generator rooms, road-tunnel niches and fertiliser fill bays need a dedicated NO₂ point tied to extract fans. XCD holds that interlock; a badge dosimeter only explains the exposure after the fact.

Selection contrast

P/NGasRangePrinciple
SPXCDULNNXNO₂0-50ppmEChem
SPXCDULNCXCO0-300ppmEChem
SPXCDULNHXH₂S0-50ppmEChem
SPXCDULNO1O₂0-25.0%VolEChem
SPXCDALMNXNO₂0-50ppmEChem
SPXCDASNNXNO₂0-50ppmEChem

XCD family matrix

Installation and wiring

Wall-mount SPXCDULNNX (nitrogen dioxide, LM25 epoxy-coated aluminium) through the one-piece plate with M8 bolts sized for that mass. This SKU uses 2 × 3/4" NPT entries: pipe kit SPXCDMTBR covers Ø1.5–3″, duct kit is SPXCDDMK, and glands must match—do not retap SPXCDULNNX. Land SPXCDULNNX 4–20 mA as three-wire and set Modbus address from the menu only. Magnetic wand calibration on the SPXCDULNNX lid stays non-intrusive. SPXCDULNNX NO₂ sits low on the exhaust wall.

FAQ

SPXCDULNNX: Does the NX cell also read NO?
SPXCDULNNX — It is specified for NO₂. If you have nitric oxide you need a different cartridge family—do not assume NX covers both.
SPXCDULNNX: What FSD options exist?
SPXCDULNNX — Default 0–50 ppm, user window 10–50 ppm in 5 ppm steps. Tunnel niches usually stay at 20 ppm FSD.
LM25 or 316SS for SPXCDULNNX (nitrogen dioxide)?
SPXCDULNNX ships in LM25 epoxy aluminium (~4.4 lb). For nitrogen dioxide in salt spray, caustic CIP or sour-water splash, switch to 316SS sibling SPXCDASNNX instead of painting this lid.
Why is SPXCDULNNX NPT instead of M20?
SPXCDULNNX is the UL/CSA nitrogen dioxide body and ships 3/4" NPT. Do not tap M20 on this lid—order ATEX sibling SPXCDALMNX if metric glands are mandatory.
Can I retrofit Modbus on SPXCDULNNX after it ships?
Modbus RTU on SPXCDULNNX is a transmitter sales option, not a jumper on the nitrogen dioxide lid. Confirm the option before the box leaves; 4–20 mA sink/source is already on this SKU.

Documents

Honeywell Sensepoint XCD datasheet / manual · On-site XCD selection matrix

Availability and enquiry

Stock is lot-based. If this aluminium ATEX box is out, jump to 316SS SPXCDASNNX or UL SPXCDULNNX rather than a dead SKU.